What needs to happen
Drag actions through the stages. Status updates flow to plant cards, MPR and system pages instantly.
Not started
6
A-115 · SKL
amberCrane #2 availability 82%, replace grab rope
Mechanical Supervisor · Due 2026-06-05
Availability risk · £7k
A-117 · SKL
redBring forward UT inspection
Plant Reliability Lead · 1 day overdue
~£30k/wk · £30k
A-118 · SKL
amberVacuum / ACC fans, 2 offline since Mon
Plant Reliability Lead · Due 2026-06-05
≈ 4 MW recoverable · £74k
A-119 · SKL
amberBag-filter ΔP creep, pulse clean optimisation
Environmental Lead · Due 2026-06-05
Availability risk · £7k
A-120 · SKL
amberAux load drift +0.2 MW MTD
Electrical Lead · Due 2026-06-05
Availability risk · £7k
A-122 · SKL
redBearing temp +4 °C in 14d
Mechanical Supervisor · 1 day overdue
~£30k/wk · £30k
Underway
2
A-116 · SKL
redSuperheater temp above corrosion-zone band
Plant Reliability Lead · Due in 2 days
~£30k/wk · £30k
A-121 · SKL
redID fan #1 vibration trending up
Mechanical Supervisor · Due in 2 days
~£30k/wk · £30k
Stuck
0
No actions
Done
0
No actions