Turbine
Ferrybridge 1 · Owner Performance Engineer
Headline indicator
76mbar(a) · Vacuum
Green band 60-90 · Amber 90-110 · Red beyond.
Recommended action
Heat-rate test next outage window; baseline bearing #3 vibration.
Owner: Performance Engineer
Open actions: 0
5 sub-KPIs · automated 5 · manual 0 · mixed 0 · needs definition 0
Data sourceAutomatedManualMixedNeeds definition
Sub-KPIs · tap any tile for full chart, history & interpretation
Vacuum
Automated76mbar(a)
Green 60-90 · Amber 90-110
Gland Steam Status
Automated1OK
Green 1-1 · Amber 0-1
Lube Oil System Status
Automated1OK
Green 1-1 · Amber 0-1
Control Oil System Status
Automated1OK
Green 1-1 · Amber 0-1
Turbine Steam Inlet Temp & Pressure
Automated465°C / 64 bar
Green 450-475 · Amber 440-480
Operating detail
Bearing vibration
2.1mm/s
Heat rate
11450kJ/kWh
Last overhaul
Oct 2024
Hours since overhaul
13640hrs